OOM202 Envitec Compatible O2 Cell for Hamilton Medical
Click To Enlarge

Envitec oxygen sensor available for use with Bird: Avea; CareFusion: Viasys Avea 16448; Covidien > Puritan Bennett : 4-074925-00, NP 840; Draeger: Infinity Delta; Emerson: Infant Flow; Hamilton Medical: 51254, Analyser, G5, Multinex, Viasys; Infrasonics: Adult Star 601T; Siemens: 9000, C/D, SV300, SV900, Servo 300, Servo 300A, Servo 700, Servo 710, Servo 900C, Servo 900D, Servo 900E, V710; Spacelabs: Capnograph; Taema: Cesar 2, Horus; Teledyne: TED 160, TED 190.

Made in Germany.

Sensor Specifications & Compatibility  
Catalog Number E61840  
Output Signal in Air 13mV - 16mV temperature compensated  
Response Time T 90% < 12 seconds  
Nominal Sensor Lifetime 1 000 000 % volume Oxygen hours  
Electrical Interface 3 pin molex  
Compatibility: Nellcor Puritan Bennett Malinckrodt  
  Mod. 740, 760, 840  
  G-0603400  
  G-062010-00  
  4-072214-00  
  G061143-00  
  G062009-00  
 
Medical Oxygen Sensors (Fuel Cells) general specifications:  
Measurement Range: 0-100 % oxygen  
Accuracy and Repeatability: < 1 % vol. O2when calibrated at 100 % O2  
Zero Ofset: < 0.5 % vol. O2in 100% N2, applied 5 minutes  
Linearity Error: < 3 % relative  
Cross Interference: < 0.5 % vol. O2response to:  
  10 % CO2balance N2  
  80% N2O balance N2  
  7.5% Halothane balance N2  
  7.5 % Isofurane balance N2  
  7.5 % Enfurane balance N2  
  9% Sevofurane balance N2  
  20% Desfurane balance N2  
Infuence of Humidity: - 0.03 % rel. per % RH at 25ðC  
Infuence of Pressure: proportional to change in oxygen partial  
  pressure  
Infuence of Mechanical Shock: < 1% relative after a fall from 1m  
Operating Temperature: 0 to 50ðC  
Temperature Compensation: built-in NTC compensation (see below)  
Efect of Temperature between +5 ðC and +25 ðC: 3 % relative error  
Compensation (steady state): between 0 ðC and +50 ðC: 8 % relative error  
Operating Humidity: 0-99 % RH non-condensing  
Long Term Output Drift: < 1 % vol oxygen per month  
  typically < - 15 % relative over lifetime  
Storage Temperature: -20 to +50 ðC  
Recommended Storage: +5 to +15 ðC  
Recommended Load: 10 kOhms  
Warm-Up Time: < 30 minutes, after replacement of sensor  
Weight: approximately 28 grams  
  approximately 43 grams E61912 series  
Designed and manufactured according to EN ISO 9001 : 2000 and EN13485 : 2003  
specifications are applicable at standard conditions: 1013 hPa, 25ðC dry ambient air

 

O2 sensor for Puritan Bennet Ventilators, PB840, PB700, PTS-2000

4-072214-00 / OXYGEN SENSOR PURITAN BENNETT 840 