Oxygen sensor for Bird 6400 and 8400, HM-11, PB7200, Hudson 5567
Click To Enlarge

Oxygen sensor for Bird 6400 and 8400, HM-11, PB7200, Hudson 5567

Oxygen Fuel Cell for Bird Ventilators 6400 and 8400

Sensor Specifications & Compatibility  
Catalog Number E61910  
Output Signal in Air 9mV 13mV temperature compensated  
Response Time T 90% < 13 seconds  
Nominal Sensor Lifetime 1 000 000 % volume Oxygen hours  
Electrical Interface 3.5mm Mono Jack  
Compatibility: Bird Mod. 6400 and Mod. 8400 ventilators  
  Bird catalog # 66030  
  Hudson 5567, V11  
  Puritan Bennett 4-020933-00 (for 7200 Vents)  
  Lifecare PLV-102  
  Hamilton HM-11  
  Miniox 406931  
  MAX13  
  Biomed devices 10006 (M-10, M-2, #4433)  
  Datascope Anestar S  
  Teleflex Medical  
  Mercury Medical 10-103-05  
  Vascular Technologies 100580  
  Phillips (Respironics) Esprit 37-079 , Criterion  
  PSR-11-917-J  
 
Medical Oxygen Sensors (Fuel Cells) general specifications:  
Measurement Range: 0-100 % oxygen  
Accuracy and Repeatability: < 1 % vol. O2when calibrated at 100 % O2  
Zero Ofset: < 0.5 % vol. O2in 100% N2, applied 5 minutes  
Linearity Error: < 3 % relative  
Cross Interference: < 0.5 % vol. O2response to:  
  10 % CO2balance N2  
  80% N2O balance N2  
  7.5% Halothane balance N2  
  7.5 % Isofurane balance N2  
  7.5 % Enfurane balance N2  
  9% Sevofurane balance N2  
  20% Desfurane balance N2  
Infuence of Humidity: - 0.03 % rel. per % RH at 25ðC  
Infuence of Pressure: proportional to change in oxygen partial  
  pressure  
Infuence of Mechanical Shock: < 1% relative after a fall from 1m  
Operating Temperature: 0 to 50ðC  
Temperature Compensation: built-in NTC compensation (see below)  
Efect of Temperature between +5 ðC and +25 ðC: 3 % relative error  
Compensation (steady state): between 0 ðC and +50 ðC: 8 % relative error  
Operating Humidity: 0-99 % RH non-condensing  
Long Term Output Drift: < 1 % vol oxygen per month  
  typically < - 15 % relative over lifetime  
Storage Temperature: -20 to +50 ðC  
Recommended Storage: +5 to +15 ðC  
Recommended Load: 10 kOhms  
Warm-Up Time: < 30 minutes, after replacement of sensor  
Weight: approximately 28 grams  
  approximately 43 grams E61912 series  
Designed and manufactured according to EN ISO 9001 : 2000 and EN13485 : 2003
specifications are applicable at standard conditions: 1013 hPa, 25ðC dry ambient air


  • Item #: B226-201
  • Manufacturer: WestPrime Healthcare
  • Manufacturer's Product Number: OOM102-1 / E61910
  • Condition: New

Oxygen sensor for Bird 6400 and 8400, HM-11, PB7200, Hudson 5567

Price: $115.00
Availability: CALL FOR MORE INFO
Reviews (0) Write a Review
No Reviews. Write a Review